Details
-
Type:
Electrical Faults (2 Weeks)
-
Status: Complete
-
Priority:
Normal
-
Resolution: Completed
-
Labels:None
-
Responsibility:Manufacturer Attending
-
Plot:Hire 7
-
Hire_or_Retail:Hire_fleet
-
Serial:2151361
-
Model:keswick
-
Year:2026
-
Size:36x12
-
ID Number:W0242634
-
Status Colour:
Complete
-
Stock_Number:42915
-
Times Scheduled:1
-
Park_Company:Golden Cap Caravan Park - WDLH
-
Park_Postcode:DT6 6JX
-
Park_Contact:Jen
-
Park_Phone:01297480010
-
Park_Email:caravanholidayhomes1@wdlh.co.uk
-
Park_Code:GOLD02
-
Park_Key_Account:Yes
-
SLA Status:
Description
CCT01 - Ring Main. Circuit has no ring end continuity on the Line conductor. Further investigation required. Neutral and CPC ring end readings are good and inline with what is expected. I suspect this is a loose connection behind one of the accessories. With the correct approach, it should be relativly straightforward to locate.
The rest of the circuits have been inspected and tested, and there are no other electrical issues to report.
This has come from our electrician.
The rest of the circuits have been inspected and tested, and there are no other electrical issues to report.
This has come from our electrician.